0

Out of 0 Ratings

Owner's of the GE Network Hardware 15A ARC FAULT BREAKER gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 42
 
Product Features
—UL Listed (Panelboards No. 67)
—60°/75°C Conductor Rating
—Suitable for Use as Service Entrance Equipment when Installed
in Accordance with the National Electrical Code
—22kAIC RMS symmetrical, Except Where Noted
—6-42 circuit devices UL Listed for bottom mounted lugs by
installing complete unit (box, interior and front) upside down.
—For a listing of CSA Listed load centers, visit geindustrial.com.
Main Lugs Factory Installed (TLM units convertible to main breaker),
Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size
Ampere 1” 1” 1/2” 1/2” 1-pole Front Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Spaces Type Feed Type
1
Number Cu-Al Ground Kit Number
40 21 41 4Surface Top 1A 14-4 TGK4 (order separately) TL240SCU
1,8
Bottom
70 21 41 4Surface Top 1A 6-3 TGK4 (order separately) TL270SCU
1,8
Bottom
125 42 83 8Combination Top 2A 1-2/0 TGL1 (order separately) TL412C
1,2,8
Flush/Surface Bottom
125 42 83 8Combination Top 2A 1-2/0 TGL1 installed TL412CT
1,2,3,8
Flush/Surface Bottom
125 42 83 8Thermoplastic Top 2 1-2/0 TGL1 (order separately) TPL412C
1,2,3,8
Bottom
125 42 83 8Thermoplastic Top 2 1-2/0 TGL1 installed TPL412CT
1,2,3,8
Bottom
125 6312 4 12 Flush Top 3A 6-1 TGL2 (order separately) TLM612FCU
4,8
Bottom
125 6312 4 12 Flush Top 3A 6-1 TGL2 (order separately) TLM612FCUD
4,8
Bottom
125 6312 4 12 Flush Top 3A 6-1 TGL2 installed TLM612FCUDG
4,8
Bottom
125 6312 4 12 Surface Top 3A 6-1 TGL2 (order separately) TLM612SCU
4,8
Bottom
125 6312 4 12 Surface Top 3A 6-1 TGL2 (order separately) TLM612SCUD
4,8
Bottom
125 6312 4 12 Surface Top 3A 6-1 TGL2 installed TLM612SCUDG
4,8
Bottom
125 8416 8 16 Flush Top 3A 6-1 TGL2 (order separately) TLM812FCU
4,8
Bottom
125 8416 8 16 Flush Top 3A 6-1 TGL2 (order separately) TLM812FCUD
4,8
Bottom
125 8416 8 16 Flush Top 3A 6-1 TGL2 (order separately) TLM812FCUDG
4,8
Bottom
125 8416 8 16 Surface Top 3A 6-1 TGL2 (order separately) TLM812SCU
4,8
Bottom
125 8416 8 16 Surface Top 3A 6-1 TGL2 (order separately) TLM812SCUD
4,8
Bottom
125 8416 8 16 Surface Top 3A 6-1 TGL2 installed TLM812SCUDG
4,8
Bottom
125 14 6 20 8 24 Combination Top 18 6-2/0 Included
10
TLM1212CCU
7,8
Flush/Surface Bottom
125 14 6 20 8 24 White Combo Top 18 6-2/0 Included
10
TLM1212CCUW
7,8,9
Flush/Surface Bottom
This table continued on next page
TLM2020CCU TPL412R
Section 1
Load Center
1PH
Main Lug
Indoor NEMA 1
Rev. 11/13
Data subject to change
without notice
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Single-Phase, Three-Wire, 120/240 Vac
Main Lugs Convertible to Main Breaker
1-9
BuyLog
Catalogwww.geindustrial.com