0

Out of 0 Ratings

Owner's of the GE Network Hardware 20A ARC FAULT BREAKER gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 42
 
Single-Phase, Three-Wire, 120/240 Vac
With Bonded Neutrals
Main
Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Bypass UL Agency Product
Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Front Type Type Incoming Certification Number
Meter Main - Ring Type, Field Installed Mains
100 21414Outdoor Semi-Flush None OH/UG UL TSL210CFCU
1
(NEMA 3R) EUSERC
100 21414Outdoor Surface
2
None OH/UG UL TSL210CSCU
1,2,3
(NEMA 3R) EUSERC
125 42636Outdoor Surface
2
None OH/UG UL TSL412CSCU
1,2,3
(NEMA 3R) EUSERC
200 42636Outdoor Semi-Flush None OH/UG UL TSL420CFCU
1,4,5
(NEMA 3R) EUSERC
200 42636Outdoor Surface
2
None OH/UG UL TSL420CSCU
1,2,3,4
(NEMA 3R) EUSERC
Meter Main - Factory Installed Mains
100 00000Outdoor Surface
2
None OH/UG UL TM10RMC
2
(NEMA 3R)
125 00000Outdoor Surface
2
None OH/UG UL TM12RMC
2
(NEMA 3R)
150 00000Outdoor Surface
2
None OH/UG UL TM15RMC
2
(NEMA 3R)
200 00000Outdoor Surface
2
None OH/UG UL TM20RMC
2
(NEMA 3R)
1
Accepts field installed fifth jaw terminal in the 3 or 9 o’clock position. Product number TJAW53; order separately.
2
Devices include removable closing cap. Order hub separately. See page 1-27.
3
Surface mounted units have two hub provisions on top end wall.
4
THQL and THHQL only, 125 amp max. TQDL is obsolete.
5
Restricted
Application Data
Main Wire Size
Product Box Unit Width Unit Height Depth Factory Inst. Field Inst. (AWG/kcmil) Equipment
Number Number (in inches) (in inches) (in inches) Svcs Disc Svcs Disc Cu-Al Ground Kit
TSL210CFCU R12 14 23-1/2 4-7/8 THQP/THQL 6-2/0 TGL1 installed
TSL210CSCU R12 14 23-1/2 4-7/8 THQP/THQL 6-2/0 TGL1 installed
TSL412CSCU R12 14 23-1/2 4-7/8 THQP/THQL 6-2/0 TGL1 installed
TSL420CFCU R14 14 30-3/4 5-3/4 THQP/THQL 1-250 TGL1 installed
TSL420CSCU R14 14 30-3/4 5-3/4 THQP/THQL 1-250 TGL1 installed
TM10RMC R32 16 17 5 TQD Field Installed
4
2-250
TM12RMC R32 16 17 5 TQD Field Installed
4
2-250
TM15RMC R32 16 17 5 TQD Field Installed
4
2-250
TM20RMC R32 16 17 5 TQD Field Installed
4
2-250
TSM2020CFCU
Section 1
Meter Socket LC
1PH
Ring Type
Meter Main
NEMA 3R
Load Centers and Circuit Breakers
PowerMark Gold Meter Socket Load Centers
1-18
BuyLog
Catalog
Rev. 11/13
Data subject to change
without notice
www.geindustrial.com
Designed and manufactured for quality applications, these
PowerMark Gold Meter Socket Load Centers are a superior
solution to specific applications. Increased durability and
reliability, maximum circuit layout flexibility and ease of
installation add up to lower total installed cost.
The Ringless UL Style meter socket load centers (Florida Meter
Group, Georgia Power, Others) are specifically designed to meet
UL requirements as well as some special features required by spe-
cific utilities. If your local utility does not require specific approval
and you need a ringless meter socket load center, use the Florida
Meter Group style.