of 42
 
Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size
Ampere 1” 1” 1/2” 1/2” 1-pole Front Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Spaces Type Type Number Cu-Al Ground Kit Number
150 32 16 0032 Combination Top 11 1-3/0 (Cu), TGK32 (order separately) TM3215CCU
Flush/Surface Bottom 2/0-3/0 (Al)
150 24 12 36 18 42 Combination Top 9 1-3/0 (Cu), TGK24 (order separately) TM2415C42
Flush/Surface Bottom 2/0-3/0 (Al) TLK32 (order separately)
150 32 16 20 10 42 Combination Top 11 1-3/0 (Cu), TGK32 and TLK20 TM3215C42
Flush/Surface Bottom 2/0-3/0 (Al) (order separately)
200 16 8 32 14 32 Combination Top 7 1-250 (Cu), TGK32 (order separately) TM1620CCU
Flush/Surface Bottom 2/0-250 (Al)
200 16 8 32 14 32 Combination Top 8 1-250 (Cu), TGK32 installed TM1620CCUG
Flush/Surface Bottom 2/0-250 (Al)
200 20 10 40 18 40 Combination Top 8 1-250 (Cu), TGK32 (order separately) TM2020CCU
Flush/Surface Bottom 2/0-250 (Al)
200 20 10 40 18 40 White Combo Top 8 1-250 (Cu), TGK24 (order separately) TM2020CCUW
3
Flush/Surface Bottom 2/0-250 (Al) TGK42 (order separately)
200 20 10 40 18 40 Combination Top 8 1-250 (Cu), TGK32 (order separately) TM2020CCUG
Flush/Surface Bottom 2/0-250 (Al)
200 20 10 40 18 40 White Combo Top 8 1-250 (Cu), TGK32 (order separately) TM2020CCUGW
3
Flush/Surface Bottom 2/0-250 (Al)
200 32 16 16 6 40 Combination Top 11 1-250 (Cu), TGK32 (order separately) TM3220CCU
Flush/Surface Bottom 2/0-250 (Al)
200 40 20 0040 Combination Top 13 1-250 (Cu), TGK42 (order separately) TM4020CCU
Flush/Surface Bottom 2/0-250 (Al)
200 32 16 20 8 42 Combination Top 11 1-250 (Cu), TGK32 and TLK20 TM3220C42
Flush/Surface Bottom 2/0-250 (Al) (order separately)
200 42 20 0042 Combination Top 14 1-300 (Cu), TGK42 (order separately) TM4220CCU
Flush/Surface Bottom 2/0-300 (Al)
225 42 20 0042 Combination Top 14 1-300 (Cu), TGK42 (order separately) TM4222CCU
Flush/Surface Bottom 2/0-300 (Al)
1
Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page 1-30. A separate TGL2 can be added in the unlikey event
that another ground bar is required.
2
No lock provision available. Use next size larger load center such as TLM1612CCU with a TDL106 accessory if locking provision is required.
3
Minimum order QTY is 40 for below 24 circuits; QTY 24 for 24 circuits and above. (See DEE-590)
Section 1
Load Center
1PH
Main Breaker
Indoor NEMA 1
Rev. 11/13
Data subject to change
without notice
Load Centers and Circuit Breakers
PowerMark Gold and Plus Main Breaker Load Centers
Single-Phase, Three-Wire, 120/240 Vac
Main Breaker Factory Installed
1-13
BuyLog
Catalogwww.geindustrial.com
Load Center
1PH
Main Breaker
Outdoor NEMA 3R
Outdoor (NEMA 3R) Enclosure
4
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size
Ampere 1” 1” 1/2” 1/2” 1-pole Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Spaces Type Number Cu-Al Ground Kit Number
100 12 5 20 8 22 Top R3A 4-1/0 TGK12 (order separately) TM1210RCU
TGK24 (order separately)
100 20 10 0030 Top R4 4-1/0 TGK24 (order separately) TM2010RCU
125 12 5 20 8 22 Top R3A 1-2/0 TGK12 (order separately) TM1212RCU
TGK24 (order separately)
125 24 12 0024 Top R4 1-2/0 TGK24 (order separately) TM2412RCU
150 8416 6 16 Top R5 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM815RCUFL
150 16 8 32 14 32 Top R5 1-3/0 (Cu), 2/0-3/0 (Al) TGK24 (order separately) TM1615RCU
TGK32 (order separately)
150 24 12 12 4 30 Top R6 1-3/0 (Cu), 2/0-3/0 (Al) TGK24 (order separately) TM2415RCU
TGK32 (order separately)
150 24 12 36 18 42 Top R39 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM2415R42
Bottom
150 32 16 0032 Top R7 1-3/0 (Cu), 2/0-3/0 (Al) TGK32 (order separately) TM3215RCU
200 8416 6 16 Top R5 1-250 (Cu), 2/0-250 (Al) TGK32 (order separately) TM820RCUFL
200 20 10 40 18 40 Top R6 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM2020RCU
TGK42 (order separately)
200 24 12 36 18 42 Top R39 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM2420R42
Bottom
200 32 16 16 6 40 Top R7 1-250 (Cu), 2/0-250 (Al) TGK32 (order separately) TM3220RCU
200 40 20 0040 Top R8 1-250 (Cu), 2/0-250 (Al) TGK42 (order separately) TM4020RCU
225 8416 6 16 Top R5 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM822RCUFL
225 42 20 0042 Top R8 1-300 (Cu), 2/0-300 (Al) TGK42 (order separately) TM4222RCU
4
100-225 amp devices have removable closing caps. Larger ampere devices require field-cut openings. Order hubs separately. See page 1-27.