Product Features
—UL Listed (Panelboards No. 67)
—60°/75°C Conductor Rating
—Suitable for Use as Service Entrance Equipment when Installed
in Accordance with the National Electrical Code
—22kAIC RMS symmetrical Short-circuit Rating Standard
—Bottom feed models available where noted with a “B” suffix.
—For a listing of CSA Listed load centers, visit geindustrial.com.
—Copper breaker mounting stabs with aluminum bus
1
Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size
Ampere 1” 1” 1” 1-pole Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Front Type Type Number Cu-Al Ground Kit Number
125 12 6412 Combination Top 4 6-2/0 TGK12 (order separately) TL12412C
3
Flush/Surface Bottom TGK24 (order separately)
Front
150 18 8618 Combination Top 7 1-3/0 (Cu), TGK24 (order separately) TL18415C
3
Flush/Surface Bottom 2/0-3/0 (Al) TGK32 (order separately)
Front
150 24 12 8 24 Combination Top 7 1-3/0 (Cu), TGK24 (order separately) TL24415C
3
Flush/Surface Bottom 2/0-3/0 (Al) TGK32 (order separately)
Front
200 18 8618 Combination Top 8 1-250 (Cu), TGK32 (order separately) TL18420C
3
Flush/Surface Bottom 2/0-250 (Al)
Front
200 30 14 10 30 Combination Top 11 1-250 (Cu), TGK32 (order separately) TL30420C
3
Flush/Surface Bottom 2/0-250 (Al)
Front
200 42 20 14 42 Combination Top 13 1-250 (Cu), TGK42 (order separately) TL42420C
Flush/Surface Bottom 2/0-250 (Al)
Front
225 30 14 10 30 Combination Top 15 1-300 (Cu), (2) TGL2 (order separately) TL30422C
4
Flush/Surface Bottom 2/0-300 (Al)
Front
225 42 20 14 42 Combination Top 15 1-300 (Cu), (2) TGL2 (order separately) TL42422C
4
Flush/Surface Bottom 2/0-300 (Al)
Front
1
Three-phase PowerMark Plus load centers have aluminum bus with copper breaker mounting stabs, providing copper-to-copper contact at breaker stabs.
2
Also UL Listed for three-phase, four-wire 240/120 Volts ac delta and three-phase, three-wire 240 Volts ac branch breakers installed.
3
Alternate main breaker: 100 Amp max. THQL (10kAIC), THHQL (22kAIC) three-pole, use retainer THQLRK. See page 1-28.
4
Not suitable for use as service entrance equipment.
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
Section 1
Load Center
3PH
Main Lugs
Indoor NEMA 1
Load Centers and Circuit Breakers
PowerMark Plus
Load Centers
Three-Phase, Four-Wire, 208Y/120 Vac
2
Main Lugs Factory Installed
1-14
BuyLog
Catalog
Rev. 11/13
Data subject to change
without notice
www.geindustrial.com