0

Out of 0 Ratings

Owner's of the GE Network Hardware 40A SP CIRCUIT BREAKER gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 42
 
Main Lugs Factory Installed
1
Outdoor (NEMA 3R) Enclosure
Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size
Ampere 1” 1” 1” 1-pole Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Type Number Cu-Al Ground Kit Number
125 12 6412 Top R3 6-2/0 TGK12 (order separately) TL12412R
2
TGK24 (order separately)
150 18 8618 Top R4 1-3/0 (Cu), TGK24 (order separately) TL18415R
2
2/0-3/0 (Al) TGK32 (order separately)
150 24 12 8 24 Top R4 1-3/0 (Cu), TGK24 (order separately) TL24415R
2
2/0-3/0 (Al) TGK32 (order separately)
200 18 8618 Top R4 1-250 (Cu), TGK32 (order separately) TL18420R
2
2/0-250 (Al)
200 30 14 10 30 Top R6 1-250 (Cu), TGK32 (order separately) TL30420R
2
2/0-250 (Al)
200 42 20 14 42 Top R8 1-250 (Cu), TGK42 (order separately) TL42420R
3
2/0-250 (Al)
225 42 20 14 42 Top R8 1-300 (Cu), TGK42 (order separately) TL42422R
3
2/0-300 (Al)
1
Also UL Listed for three-phase, four-wire 240/120 Volts ac delta and three-phase, three-wire 240 Volts ac branch breakers installed.
2
Alternate main breaker 100 Amp max. THQL (10kAIC), THHQL (22kAIC) three-pole, use retainer THQLRK. See page 1-28.
3
Not suitable for use as service entrance equipment.
Main Breaker Factory Installed
4
Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size
Ampere 1” 1” 1” 1-pole Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Front Type Type Number Cu-Al Ground Kit Number
100 12 6412 Combination Top 6 6-1/0 (Cu), TGK12 (order separately) TM12410C
5
Flush/Surface Bottom 4-1/0 (Al) TGK24 (order separately)
Front
100 18 8618 Combination Top 6 6-1/0 (Cu), TGK24 (order separately) TM18410C
5
Flush/Surface Bottom 4-1/0 (Al) TGK32 (order separately)
Front
125 30 14 10 30 Combination Top 11 1-3/0 (Cu), TGK32 (order separately) TM30412C
Flush/Surface 2/0-3/0 (Al)
Front
125 30 14 10 30 Combination Bottom 11 1-3/0 (Cu), TGK32 (order separately) TM30412CB
Flush/Surface 2/0-3/0 (Al)
Front
150 24 12 8 24 Combination Top 11 1-3/0 (Cu), TGL1, TGL2, TGL20,TNG3, TM24415C
Flush/Surface 2/0-3/0 (Al TGN6 (order separately)
Front
150 24 12 8 24 Combination Bottom 11 1-3/0 (Cu), TGK32 (order separately) TM24415CB
Flush/Surface 2/0-3/0 (Al)
Front
150 30 14 10 30 Combination Top 11 1-3/0 (Cu), TGK32 (order separately) TM30415C
Flush/Surface 2/0-3/0 (Al)
Front
150 30 14 10 30 Combination Bottom 11 1-3/0 (Cu), TGK32 (order separately) TM30415CB
Flush/Surface 2/0-3/0 (Al)
Front
150 42 20 14 42 Combination Top 13 1-3/0 (Cu), TGK42 (order separately) TM42415C
Flush/Surface 2/0-3/0 (Al)
Front
150 42 20 14 42 Combination Bottom 13 1-3/0 (Cu), TGK42 (order separately) TM42415CB
Flush/Surface 2/0-3/0 (Al)
Front
200 24 12 8 24 Combination Top 11 1-300 (Cu), TGK32 (order separately) TM24420C
Flush/Surface 2/0-300 (Al)
Front
200 24 12 8 24 Combination Bottom 11 1-300 (Cu), TGK32 (order separately) TM24420CB
Flush/Surface 2/0-300 (Al)
Front
4
Also UL Listed for three-phase, four-wire 240/120 Volts Hi leg delta and three-phase, three-wire 240 Volts ac branch breakers installed.
5
100 Amp indoor devices UL listed for bottom-feed by installing complete unit upside-down.
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
This table continued on next page
Section 1
Load Center
3PH
Main Lugs
Outdoor NEMA 3R
Rev. 11/13
Data subject to change
without notice
Load Centers and Circuit Breakers
PowerMark Plus
Load Centers
Three-Phase, Four-Wire, 208Y/120Vac
Main Circuit Breaker or Main Lugs Factory Installed
1-15
BuyLog
Catalogwww.geindustrial.com
Load Center
3PH
Main Breaker
Indoor NEMA 1
TM24420CB