Product Features - Generator Panels
—Suitable for use in accordance with Article 702 of the National
Electrical Code, ANSI/NFPA 70
—Single-phase, 2 interlock 60A or 30A main breakers, 8 circuits
max.
—Safety and convenience when using a generator - 14,000 peak
wattage, 11,520 continuous load, 48 amps at 240 volts.
—Maintains power to such critical circuits as those for furnace,
pump, refrigerator, lights.
—Connected dual breaker mechanism ensures that only one
source is active at a time.
Generator Panels, Two Interlocked Main Breakers Factory Installed
Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size
Ampere 1” 1” 1/2” 1/2” 1-pole Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Spaces Front Type Type Number Cu-Al Ground Kit Number
30 42 8 4 8Flush Front Top 3A 6-1 TGK12 included TM830FCUGEN
Bottom
30 42 8 4 8Surface Front Top 3A 6-1 TGK12 included TM830SCUGEN
Bottom
60 42 8 4 8Flush Front Top 3A 6-1 TGK12 included TM860FCUGEN
Bottom
60 42 8 4 8Surface Front Top 3A 6-1 TGK12 included TM860SCUGEN
Bottom
Generator Panels, Two Interlocked Main Breakers Factory Installed
Outdoor (NEMA 3R) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size
Ampere 1” 1” 1/2” 1/2” 1-pole Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Spaces Type Number Cu-Al Ground Kit Number
30 42 8 4 8 Top R2A 6-1 TGK12 included TM830RCUGEN
60 42 8 4 8 Top R2A 6-1 TGK12 included TM860RCUGEN
Riser Panels
Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size
Ampere 1” 1” 1/2” 1/2” 1-pole Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Spaces Front Type Type Number Cu-Al Ground Kit Number
125 20 10 40 20 40 Combination Top 9A 6-2/0 TGK12 (order TLM2012CCURP
Flush/Surface Front separately)
Tap kits required, order separately. See page 1-29.
Auxiliary gutters available. See page 1-29.
Spa Panels
Outdoor (NEMA 3R) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size
Ampere 1” 1” 1/2” 1/2” 1-pole Load Center Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Spaces Type Type Number Cu-Al Ground Kit Number
125 42 8 4 8Factory Included Top 1-2/0 TGL1 installed TL412R250GF
50A GFCI Bottom
125 42 8 4 8Factory Included Top 1-2/0 TGL1 installed TL412R260GF
60A GFCI Bottom
Twist Lock Power Inlets
Product
Receptacles Amps Volts UL Number
L14-20 20 120/240 Canada, US T020N
L14-30 30 120/240 Canada, US T030N
CS637 50 120/240 Canada, US T050N
TL412R250GF TM830FCUGEN
Section 1
Load Center
Generator Panels
Riser Panels
Spa Panels
Rev. 11/13
Data subject to change
without notice
Load Centers and Circuit Breakers
PowerMark Gold Load Centers
Single-Phase, Three-Wire, 120/240 Vac
1-17