of 42
 
Ring Type - Farm Panel - Main Breaker
Main
Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Front Bypass UL Agency Product
Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Front Type Type Incoming Certification Number
200 42 8 3 8Outdoor Surface None OH/UG UL TSF420CSCU
1,2
(NEMA 3R) EUSERC
1
Devices include removable closing cap. Order hub separately. See page 1-27.
2
Separate field mounted service disconnect can be added, THQL/THHQL. See wiring diagram on page 1-35.
Application Data
Main Wire Size
Product Box Unit Width Unit Height Depth Factory Inst. Field Inst. (AWG/kcmil) Equipment
Number Number (in inches) (in inches) (in inches) Svcs Disc Svcs Disc Cu-Al Ground Kit
TSF420CSCU R16 16-3/4 33 6-3/16 THQMV THQL/THHQL 1-300 TGK12 (order separately)
Ring Type Feed-Thru - Main Breaker
Main
Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Front Bypass UL Agency Product
Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Type Type Incoming Certification Number
150 42838Outdoor Surface None OH/UG UL TSM415CSCU
1
(NEMA 3R
150 8416 6 16 Outdoor Surface None OH/UG UL TSM815CSCU
1
(NEMA 3R)
150 8416 6 16 Outdoor Surface None OH/UG UL TSM815CSFL
1
(NEMA 3R)
200 42838Outdoor Surface None OH/UG UL TSM420CSCU
1
(NEMA 3R)
200 8416 6 16 Outdoor Surface None OH/UG UL TSM820CSCU
1
(NEMA 3R
200 8416 6 16 Outdoor Surface None OH/UG UL TSM820CSFL
1
(NEMA 3R)
1
Devices include removable closing cap. Order hub separately. See page 1-27.
Application Data
Main Wire Size
Product Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment
Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSM415CSCU R36 14 28-1/2 4-1/2 THQMV 6-350 TGL2 included
TSM815CSCU R16 16-3/4 33 6-3/16 THQMV 1-300 TGK12 (order separately)
TSM815CSFL R37B 14 31-3/4 4-1/2 THQMV 6-350 TGK24 included
TSM420CSCU R36 14 28-1/2 4-1/2 THQMV 6-350 TGL2 included
TSM820CSCU R16 16-3/4 33 6-3/16 THQMV 6-350 TGK12 (order separately)
TSM820CSFL R37B 14 31-3/4 4-1/2 THQMV 6-350 TGK24 included
Section 1
Meter Socket LC
1PH
Ring Type
Farm Panel
Main Breaker
NEMA 3R
Rev. 11/13
Data subject to change
without notice
Load Centers and Circuit Breakers
PowerMark Gold Meter Socket Load Centers
Single-Phase, Three-Wire, 120/240 Vac
With Bonded Neutrals
1-19