of 27
 
Wiring diagram
Wiring in Motor housing
on top side (Rear cover side)
RP1800F with LED Job Light
Fig. D-3E
Lead wire holder
Support Unit
When putting Support unit’s Lead wires
into Lead wire holders, put them as follows.
* Support unit’s Lead wire (black)
into Lead wire holder of outside
* Support unit’s Lead wire (orange)
into Lead wire holder of inside
Power supply
circuit
Support unit’s Lead wire (orange) Support unit’s Lead wire (black)
Put Power supply
circuit into the above
illustrated position.
Wiring in Grip (R)
RP1800F with LED Job Light
Insulated connector
Connect Insulated connector to
Switch terminal 2, keeping it
away from the Boss.
Switch terminal 2
Boss
P 24/ 27