[3] DISASSEMBLY/ASSEMBLY
[3]-2. Armature, Motor bracket complete (cont.)
DISASSEMBLING
Fig. 13
Fig. 14
Fig. 15
(3) Armature can be removed in the manner A or B shown in Fig. 13. Remove Ball bearing 629DDW from Armature.
(4) Disassemble the Motor bracket as illustrated in Figs. 14 and 15.
Motor bracket
Remove Ball bearing
629DDW with 1R269.
Remove Bearing retainer 60 by unscrewing
M4x14 Countersunk head screw.
In case of Models RP1800F, RP1801F,
RP2300FC and RP2301F, remove LED
Circuit by removing Bind CT4x12
Tapping screw (2pcs.)
A: Supporting Motor bracket with 2 pcs.
of 1R258, remove Armature with
Arbor press.
1R258
Armature
Bearing retainer 60
Ball bearing
6205DDW
Remove Ball bearing
6205DDW by striking
Motor bracket with
Plastic hammer.
Bind CT4x12
Tapping screw (2pcs.)
4x12 Tapping
screw (2pcs.)
M4x14 Countersunk
head screw (3pcs.)
LED circuit
Grip cover L
Remove Grip cover L by unscrewing
4x12 Tapping screw (2pcs.)
Grip L can be removed by unscrewing
M6x25 Pan head screw.
Grip L
M5x12 Pan
head screw Lock lever
Remove Lock lever by unscrewing
M5x12 Pan head screw.
Separate M10 Set bolt and Torsion
spring 15 from Lock lever.
Torsion spring 15
M10 Set bolt
M6x25 Pan head screw
Motor bracket
Ball bearing
629DDW
Armature
1R269
Repair
B: Strike Motor bracket with Plastic
hammer while gripping Armature.
P 7/ 27